RU500T35 Series Technical Information
Replacement Filters
Part No: 93023
Description: 5 Micron Sediment Cartridge
Replacement Time: Up to a Year*
Part No: UDF10HP
Description: 10” GAC Cartridge
Replacement Time: Up to a Year*
Part No: OCB
Description: Carbon Prefilter
Replacement Time: Up to a Year
Part No: TFC-RO
Description: 35 GPD TFC membrane
Replacement Time: Up to 18 months
Part No: IL210C
Description: Carbon Postfilter
Replacement Time: Up to a Year
Part No: UST-200 RL (with UV Option)
Description: 6 watt UV Replacement Lamp
Replacement Time: Annually
Filter Specifications
Pre-Filter: 93023
Construction: 100 % Pure Polypropylene Fibers
Temperature Range: 40-145° F (4.4 -62.8°C)
Maximum Flow Rate: 5 gpm (19 lpm)
Dimensions: 2 - 3/8 in. x4-7/8 in. (61mm x 124 mm)
Micron Rating: 5 µm Nominal
Initial Pressure Change: 2.00 psid @1.0 GPM
Fits all Standard 10 in. Housings
Meets FDA Requirements for food and beverage contact.
Filter: UDF10HP
Vibration Packed Granular Activated Carbon
Carbon Wt.: 0.75 lbs. Iodine Rating No. 1100
Temperature Range: 40° to 125ºF (4.4° to 52° C)
Maximum Flow Rate: 1.0 gpm (3.875 lpm)
Dimensions: 2- 7/8 in. x 9 3/4 in. (73 X 248 mm)
Micron Rating: 5 µm Nominal
Initial Pressure Change: 2.00 psid @1.0 GPM
Chlorine Reduction: 2,500 Gal. @ 1.0 GPM
Fits all Standard 10 in. Housings
Cartridge is Tested and Certified by International
ANSI/NSF Standard 42 - Conforms to requirements.
Post Filter: OCB
Construction: Granular Activated Carbon
Temperature Range: 40° to 125ºF (4.4° to 52° C)
Maximum Flow Rate: 1 gpm(3.875 lpm)
Housing Inlet / Outlet Size: 1/4 in. O.D. tube female
Quick Connect x 1/4 in. MNPT
Dimensions: 2- 7/8" x 9 3/4" (73 X 248 mm)
Micron Rating: 5 µm Nominal, Iodine No. 1100
Initial Pressure Change: 2.00 psid @1.0 GPM
Chlorine Reduction: 2,500 Gal. @ 1.0 GPM
Carbon Wt.: 0.75 lbs. Fits all Standard 10" Housings
Cartridge is Tested and Certified by International
ANSI/NSF Standard 42 - Conforms to requirements.
Membrane: TFC-RO
Construction: Thin Film Cellulose
Temperature Range: 40° to 85°F (4.4° to 29.5° C)
Maximum Flow Rate: 1 gpm(3.875 lpm)
Dimensions: 1.75" x 11 3/4" (44.5 X 298.5 mm)
TDS Rejection : 90 - 98%
Test Feed Conditions: 500 PPM
San Diego Tap @65 PSI and 77°F.
Maximum Feed Turbidity: 1 NTU
Maximum Pressure: 125 PSI
Chlorine Residual: 2.0 PPM Max. / 0.2 PPM Min.
All Materials meet FDA requirements and meets
or complies with NSF Standard 58.
Post Filter: IL210C
Construction: Granular Activated Carbon
Temperature Range: 40° to 125ºF (4.4° to 52° C)
Maximum Flow Rate: 1 gpm (3.875 lpm)
Dimensions: 2" x 10"
Micron Rating: 5 µm Nominal
Initial Pressure Change: 2.00 psid @1.0 GPM
Chlorine Reduction: 2,500 Gal. @ 1.0 GPM
Carbon Wt.: 0.75 lbs.
Cartridge is Tested and Certified by International
ANSI/NSF Standard 42 - Conforms to requirements.
Ultraviolet Lamp: UST-200 RL (with UV Option)
Construction: 316 Bonded Stainless Steel Interior
Temperature Range: 40-105° F (4.4 - 40°C)
Maximum Flow Rate: 1.0 gpm (3.875 lpm)
Dimensions: 2 in. O.D. x 11.50 in. L (51 mm x 292 mm)
U.V Rating Output: 30,000 micro-watts at maximum flow
Watts: 6 Ports: 1/4 in.
UV Module meets or complies with NSF Standard 55
All materials meet FDA or NSF requirements. The UV
unit was effective in killing (> 99%) E-coli and
significantly reducing the level of micrococcus luteus.
Booster Pump: CDP 6000 (Optional for either unit; specify unit w/BP)
The booster pump is used with a reverse osmosis system to boost inlet water pressure. The unique design features of the pump provide superior performance characteristics to deliver a near constant “boost” pressure to the R. O. membrane in low inlet water pressure applications or extreme conditions that effect pressure over the membrane.
Along with mechanical and electro-mechanical options, booster pumps enhance RO systems in the following ways:
• Monitoring performance
• Improving membrane efficiency
• Conserving water
• Conserving power
• Shutting down the pump when continuous product water is not necessary
Booster pumps P6000 are recommended in reverse osmosis applications where feedwater pressure is less than 40 PSI. Feedwater high in Total Dissolved Solids (TDS) may need a boost, in order to perform within rejection parameters.
FACT: Over 500 mg/l or ppm TDS, the PSI will be reduced by 1 PSI for every
100 TDS.
For Example; Feedwater that is 2,000 mg/l of TDS will reduce PSI by 15. A booster pump will compensate to allow for proper application. On well-water, know your water pressure (PSI) and your TDS.
System Parameters
Tubing Size: 1/4 in. O.D.
System Weight: 27 lbs. 12.3 Kgs.
System Size: 17"W x 16"L x 17"H (43 cm x 41 cm x 43 cm)
Min/Max Water Temperature: 40º / 80 ºF - 4.4 / 62.8C
Max Water Pressure: 75 PSI / 5.86 Bar
Housing Inlet / Outlet Size: 1/4 in. O.D. tube female
Quick Connect x 1/4 in. MNPT
Flow Rate : <1.0 GPM / 3.78 LPM
Shipping Information
Carton Size.:17"W x 16"L x 17"H Carton Wt.:27 lbs. / 12.3 Kgs.
For other performance requirements or applications, other models are available.
*Based on local water conditions and usage.
Technical Information
Complete set-up, installation, start-up and schematics available in all service guides included with unit.
Click here for PDF Booklet on RU500T35 Series
Product Service Guide
Product Compliances
Product Warranty
Conditions of Sale
|